For more information
+0805 725 8015
Title Image

Product

Clinical Chemistry

BM 500

– Throughput – up to 400 tests/hour (560 with ISE)
– ISE module for Na, K, Cl as option
– Build-in barcode reader for samples and reagents
– Reaction cuvettes – reusable 100 reaction cuvettes
– 8 steps cuvettes washing system
– Wavelengths – 12 wavelengths in the range 340 to 800 nm
– Two arm for mixing of sample and reagents
– Sample probe – with liquid level detection and collision protection
and clot detector
– The volume of dispensed sample – 2-45 μl
– Up to 4 reagents in one reaction
– The volume of reagent dispensed – R1, R3 – 150-350 μl,
R2, R4 – 20-250 μl
– Positions for reagents – 80 bottles 20, 30 ml and 70 ml,
cooled to 2-10°C
– Positions for samples – 100 tubes with diameter 12 – 14 mm
height 35-100 mm, microcups
– Connection to LIS – HL7 protocol

BM 200 2nd Generation

  • Throughput – 240 tests/hour (without ISE), 360 tests/hour
  • (with ISE Na, K, Cl)
  • Optional build-in PC
  • Special anti-noise and high ergonomic design
  • Methodology – end-point, two-point and kinetic,
    colorimetric and turbidimetric measurement
  • QC – Westgard, Multi rules and L-J rules
  • Conection to LIS – HL7 Protocol
  • Barcode reader for sample and reagents
  • Water consumption – max 2,5 l/hour
  • Optional ISE module
  • Optional Touch screen
  • 40 sample positions – no special positions for calibrators,
    controls and stat samples-possibility of use as many controls
    and calibrators as needed
  • Up to 5 virtual sample trays
  • 40 reagent positions, possible input 2 lots of the same reagent
  • or share reagent between tests
  • Possible reagents recognition by barcode reader
  • Refrigerated sample/reagent compartment 4-10°C
  • Real time reagent volume monitoring
  • 81 reaction cuvettes with special ultraviolet transmitting material
  • Hot air thermostat
  • Full-sealed matrix spectrometric system
  • 8 wavelengths from 340-670 nm, 800 nm optional
  • Halogen lamp with 2000 working hours life
  • Sample and reagent probe with liquid level detection
    and 3-D collision protection.
  • Maintenance free dilutor
  • Minimum reaction volume – 150 μl
  • Contamination free sample probe and stirrer

BM 300

  • Throughput – 300 tests/hour (without ISE), 420 tests/hour
    (with ISE Na, K, Cl)
  • Optional: ISE module, Internal PC with touch screen, barcode reader
  • High ergonomic design (special place for reagents screw
    and reaction cover)
  • Cuvette washing system: 6-step wash station with washing solution
  • 81 high light transmittance reaction cuvettes, optional quartz
    glass cuvettes
  • Anti-contamination design (automatic probe and mixer washing,
    intelligent anti-contamination program, carry-over contamination
    rate ≤ 0.005%)
  • Anti-noise design (silent water cooling, operating noise < 65dB)
  • Sample and Reagent tray – 40 positions for reagent, 40 positions
    for sample with STAT priority
  • Refrigerated sample/reagent compartment 4-10°C
  • Hot air thermostat for reaction cuvette
  • Minimum reaction volume – 150 μl
  • Longest reaction time – 15 min (single reagent); 12 min (double reagents)
  • Test method -Endpoint, Two-point, Kinetic, Colorimetric,Turbidimetric
  • Cal method – Linear (single-point, two- and multi-point), Logit-4P,
    Logit-5P, spline, exponential, polynominal
  • Wavelengths (nm) – 340, 405, 450, 510, 546, 578, 630, 670, optional 800
  • Halogen-tungsten lamp with > 2000h life time
  • Overall water consumption : < 6,5 l/hour;
  • User friendly software (multi-language; easy operating with iconic
    interface; powerful statistic system; manual dilution; auto dilution
    and post dilution; easy rerun and restore test)
  • Calibration and QC (Multiple calibration module, Advanced algorithm to obtain
    best calibration curve; Multi QC rules: Westgard, Cumulative sum check, Twin plot)
  • Real Time Monitoring (reaction, calibration and QC test curve; sample, reagent
    and reaction cuvette status; lamp intensity, distilled water and waste tank;
    reaction and reagent disk temperature).

BM 100

  • Throughput – up to 150 tests/hour (560 with ISE)
  • Build-in barcode reader for samples and reagents
  • Reaction cuvettes – reusable 81 reaction cuvettes
  • Wavelengths – 8 wavelengths in the range 340 to 670 or 800 nm
  • Additional arm for mixing of sample and reagents
  • Sample probe – with liquid level detection and collision protection
  • and clot detector
  • The volume of dispensed sample – 2-30 μl
  • The volume of reagent dispensed – R1: 150–300 μl; – R2: 20–300 μl
  • Reaction volume – 150 – 500 μl
  • Positions for reagents – 40 bottles 20, 30 ml, cooled to 4-10°C
  • Positions for samples – 40 tubes with diameter 12 – 14 mm, height 35-100 mm, microcups
  • Water consumption 1,5 L / hour.

BM 50

Semi-automatedclinical chemistry analyzer

Incubator: 8 incubation positionsLight Source: 6V/10W halogen lamp

Wavelength: 340,405,505,546,578,630,700 nm

Self- diagnostic system

Sample volume 200-800 uL

Method: turbidimetric and colorimetric

Languages: english, spanish, french, italian

Built-in thermal printer

Weight – 3 kg

Dimentions: 34 x 22 x 10 cm

Electrolyte Analyzer

BM ISE

Models:
K+ / Na+ / Cl-
K+ / Na+ / Cl- / Ca2+ / pH

– Principle – direct measurement by Ion Selective Electrode (ISE)
– Sample – whole blood, serum, plasma, urine, CSF
– Sample volume – 65 μl, 100 μl, 150 μl
– Throughput – up to 80 samples/hour
– Data storage- up to 10 000 patients results
– Calibration – automatic or manual
– Output – internal thermal printer, RS-232 serial port
– Dimensions – 340 mm × 200 mm × 380 mm (L×W×H)
– Weight – Main unit – 6 kg; autosampler – 2 kg
– Reagent pack volume – solution A 430 ml; solution B 110 ml, max. 350 tests

Options :

– Autosampler – 35 positions for samples, 5 positions for emergency
– 2 positions for QC, 2 positions for maintenance, second needle, sensor for sample cups
– Barcode Scanner

Hematology Analyzer

BM HEM 5TS

Automated hematology analyzer

 

– Throughput – 60 tests/hour
– Parameters – 27 hematology parameters, including 5-DIFF,
– 4 scattergram, 2 histograms
– WBC, Lym%, Lym#, Mon%, Mon#, Neu%, Neu#, Eos%, Eos#, Bas%,Bas#,
RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT
– Research parameters – LIC%, LIC#, ALY%, ALY#
– Test mode – CBC, CBC+DIFF
– Counting modes – whole blood, capillary blood and prediluted
– Sampling method – open tube mode
– Measuring technology – Semiconductor laser flow cytometric
analysis, automatic pulse resistance method (WBC/RBC/PLT )
– Sample volume – 15 μl blood sample for whole blood mode,
– 20 μl prediluted mode
– Reagents – 3 reagents, cyanide free

BM HEM 3

Automated hematology analyzer

 

  • Throughput – 80 tests/hour
  • Parameters – 22 hematology parameters, including 3-DIFF
  • WBC, LYM, MID, GRA, LYM%, MID%, GRA%, RBC, HCT, MCV, HGB, MCH,
    MCHC, PLT, PCT, MPV, P-LCC, P-LCR, RDW-CV, RDW-SD, PDW-CV, PDW-SD
  • Sampling method – open tube system with automatic sample rotor
  • Sample volume – 25 μl whole blood or 50 μl in predilute mode
  • Reagents – 3 cyanide-free reagents – Diluent, Lyse, Cleaner
  • Clog prevention – high-voltage burst on aperture in each analysis
    cycle and high pressure back-flush
  • Data capacity – 10 000 results, including RBC, PLT, and WBC 3-part histogram
  • User interface – easy to use, menu driven with touchscreen, separate
  • START button and status LED
  • Languages available – English, Polish, Spanish, French, Romanian,
  • Russian, Indonesian, German, Italian, Korean, Chinese and Vietnamese

Urine Analyzer

BM URI 200

  • Parameters – pH, Nitrite, Specific Gravity, Ascorbic Acid, Blood,
    Glucose, Bilirubin, Urobilinogen, Ketone, Leucocytes, Protein
  • Measurement principle – dual wavelength reflectance method
  • Measuring wavelength-3 LED wavelength (550, 620, 720 nm)
  • Throughput – 60 tests/hour (standard mode); 120 tests/hour (fast mode)
  • Memory capacity – 4000 results
  • Interface – serial port (RS 232), parallel port (for external printer),
    PS/2 (for barcode reader)
  • Cold light source facility with long life and high stability

BM URI 500

– Parameters – pH, Nitrite, Specific Gravity, Ascorbic Acid, Blood,Glucose,
Bilirubin, Urobilinogen, Ketone, Leukocytes, Protein, Creatinine, Calcium, Microalbumin
– Measurement Principle-dual wavelength reflectance method
– Measuring wavelength – 3 LED wavelength (550, 620, 720 nm)
– Throughput – 520 tests/hour
– Memory capacity – 5000 results
– Interface – serial port (RS232), parallel port (for external printer), PS/2 (for barcode reader)
– Control function-self-checking, sample testing and malfunction
detection are controlled by inbuilt microcomputer
– Cold light source facility with long life and high stability
– Abnormal tests reports
– Urine color determination
– Urine clarity determination

PLATE  AUTO-WASHER

PLATE WASHER is an automated washer for micro-plates with 96 wells. Original and versatile aspirate and dispense system: less than 3 µl of residue washing liquid. The software powerful and versatile, is able to manage and memorize as much as 100 washing programs. Programmable incubation capability. In combination with the Plate Reader it turns out to be a complete work station for the washing and reading of ELISA tests. The software allows the operator to execute any washing cycle; parameters setting through keyboard and display.

Consumables

Butterfly Needle
Chemistry Reagents
Plain Vacutainer
Rapid Test Kit